Troubleshooting your lynx grill, Before you call for service – Lynx Professional Grills 27" Free Standing Grill L27PSR-2 User Manual

Page 19

Advertising
background image

19

prosear™ 2 burner

it’s easy to keep your

prosear™ 2 burner operating

at peak performance. Just run

it on “hi” with the hood open

for 5 minutes after each use to

burn away any food particles

or drippings.
any ash accumulation on the

burner screen can be removed

with a light brush or vacuum

… But wait until the

BuRneR is cool!

TROUBLESHOOTING YOUR LYNx GRILL

before you call for servIce

please check a few things before calling for service

:

is there fuel supplied to the grill?

is the main shut-off valve open?

are you using the correct type of fuel? (lp or natural gas)

(See INDEX: “Gas Requirements” for further

details.)

Is your propane cylinder empty? Have you recently refilled the propane cylinder? If so, is the

connection tight?

have you opened the valve on the propane cylinder?

is the grill plugged in to a live electric circuit?

if you’ve checked the above items, review the trouble-shooting list below before calling for lynx for

service.

heat shield Removed,

Orifice/Venturi Position

every 3 to 6 months, remove

the burner and inspect the

venturi (inlet) and orifice to

ensure that they’re free of

obstructions.
food debris on the inside

of the burner can be gently

shaken out. do not touch

the ceramic surface.

Inside View, Orifice all

the way into venturi

when re-installing the

prosear™ 2 burner, be sure to

correctly position the burner.

Advertising