Updating shares manually, Testing failover, Updating shares manually -16 – HP Storage Mirroring V5 Software User Manual

Page 138: Testing failover -16

Advertising
background image

16

-

16

The following table identifies how the visual indicators change as the status of failover changes.

Updating shares manually

Share information can be manually updated from the Failover Control Center window. To manually update the share
information, highlight a source machine in the

Monitored Machines

tree and click the

Update Shares

button.

Testing failover

The failover process, including script processing, can be tested at any time. To force unavailability, disconnect the network
cable from a monitored machine, wait for the

Time to Fail

counter to decrease to zero and failover begins. To avoid the

countdown delay, highlight the monitored machine name in the Failover Control Center window and select

Failover

.

Time to Fail

Countdown

Status Bar

Colored Bullets

Desktop Icon

Tray

Source is Online

The Time to Fail counter
is counting down and
resetting each time a
response is received
from the source machine.

The status bar
indicates that the
target machine is
monitoring the
source machine.

The bullets are
green.

a

a. When the

Time to Fail

value has decreased by 25% of the entire timeout period, the bullet changes from green

to yellow, indicating that the target has not received a response from the source. The yellow bullet is a caution signal.
If a response from the source is received, the countdown resets and the bullets change back to green. If the
countdown reaches zero without the target receiving a response from the source, failover begins.

The Windows
desktop icon tray
contains a failover
icon with red and
green computers.

Source Fails and

Failover is

Initiated

The Time to Fail
countdown value is 0.

The status bar
displays the source
machine and IP
address currently
being assumed by
the target.

The bullets are red.

The Windows
desktop icon tray
contains a failover
icon with red and
green computers.

Failover is
Complete

The Time to Fail counter
is replaced with failed
message.

The status bar
indicates that
monitoring has
continued.

The bullets are red.

The Windows
desktop icon tray
contains a failover
icon with a red
computer.

Advertising