7.

When you finish configuring event notification, click OK.

The System Options window opens. You will now receive only events of the severity you
selected.

Selecting individual events

To select which individual events cause an SNMP notification message to be sent:
1.

From the Initialized Storage System Properties window, click System options.

The System Options window opens.

2.

Under notification, select Configure SNMP/event log notification.

3.

Select Configure events for SNMP/event log notification.

4.

Under Configure events individually, select one or more event levels.

5.

Under Configure events individually, click Configure.

The Set Event Notification Options window opens. The events that appear in this window are
determined by your selection of a severity level.

6.

From this window, you can select individual events for notification.

7.

When you finish making your selections, click Save changes.

The Configure Event Notification window opens.

8.

Click OK.

The System Options window opens. You must configure host notification for your event
configuration to take effect.

NOTE:

If you have configured an array event, two SNMP traps are sent for the configured event-

one for the storage cell event and other one for the management event. The notification code for
an array event starts from 34000.

Applying a customized event configuration file

To apply your customized event configuration file to HP P6000 Command View:
1.

From the Initialized Storage System Properties window, click System options.

The System Options window opens.

2.

Select Configure SNMP/event log notification.

3.

Select Configure events for SNMP/event log notification.

4.

Under Configure events using a configuration file, click Browse.

5.

Locate and select the event configuration file you created.

6.

On the Configure Event Notification window, click Configure.

7.

Click OK.

Retrieving the parse file

The parse file provides HP P6000 Command View with a human-readable description for each
event code generated by the array controllers. The parse file contains the hexadecimal event code
and event description, an explanation of the event, and the array component to which the event
refers. Every release of the controller software contains an updated parse file.

If the event description displays Description not found in parse file, you must update
the parse file that the controller uses to populate the event description. This can occur if you upgrade
or install HP P6000 Command View on a management server that has not previously run this
software.