7 commissioning, Commissioning the complete system, Fig. 18 commissioning the dgpi(l) – Festo Линейный привод с датчиком перемещения DGPIL User Manual

Page 29: 7commissioning

Advertising
background image

DGPI(L)−...−AI F

Festo DGPI(L)−...−AIF 0409a English

29

7

Commissioning

Commissioning the complete system

S

Slowly pressurize the complete system.

In this way you will prevent sudden unĆ
controlled movements.

For slow start−up pressurization, use
safety start−up valve type HEL−.../HEM−...Ă.

Commissioning the DGPI(L)−...

Warning
S Make sure that:
Ĉ nobody can place his/her hand in the path

of the moveable mass (e.Ăg. by providing a
protective grill).

Ĉ there are no objects in its path.

It must not be possible to touch the
DGPI(L)−... until the mass has come to a
complete stand.

Control with SPC11/200:

1. Note the stroke reduction per end position.

Only limited positioning behaviour is available
within the stroke reduction.

DGPI(L)−...

25

32

40...80

Cushioning length d

18 mm

20 mm

30 mm

Stroke reduction r

25 mm

25 mm

35 mm

At the factory it is intended that the pneumatic end position cushioning is
open completely on both sides when the device is controlled by the
SPC11/200.

QH−...

HEL−...

Fig. 17

Fig. 18

Fig. 19

d

r