Control requirement, Hardware connection – Delta DVP-ES2 User Manual

Page 677

Advertising
background image

7 C AN o p e n F u n c t i o n a n d O p e r a t i o n

7 - 2 1

‹

Emergency response data

Response message

PLC device

High byte

Low byte

D6000 ReqID=01

Status

code

=01

D6001

Reserved =0

Size =2A (Hex)

D6002

Message

header

Type =04

Node ID =02

D6003

Total number of data =1

Number of data stored =1

D6004

Datum 1=54

Datum 0=42

D6005

Datum 3=15

Datum 2=20

D6006

Datum 5=0

Datum 4=0

D6007

Datum 7=0

Datum 6=0

D6004

Datum 1=54

Datum 0=43

D6005

Datum 3=14

Datum 2=20

D6006

Datum 5=0

Datum 4=0

D6007

Message

data

Datum 7=0

Datum 6=0

7.4.4 Example on Sending SDO through the Ladder Diagram

¾

Control Requirement:

Read the value of P0-09 of servo in cycle through SDO.

¾

Hardware Connection:

DVP32ES2-C

PC

TAP-CN03

Y5

UP0

Y0

Y1

Y3

Y2

Y4

Y10

Y7

Y6

UP1

Y12

Y11

Y13

+24V

L

N

NC

X5

X1

S/S

24G

X0

X3

X2

X4

X11

X7

X6

X10

X13

X12

X14 X15

Y16

Y15

Y14

Y17

X17

X16

ZP1

ZP0

CAN+

SG

+

D

D

-

CAN-

ASDA-A2-xxxx-M

CANopen

CANopen

RS-232

¾

The Corresponding Relation between Slave Parameter and Index/Subindex
The index_subindex corresponding to P0-09 of servo is 2009_0. On the interface of the
network configuration software, right click the servo icon; select “Parameter Edit” and then the
following dialog box will appear. You can see the index_subindex corresponding to the servo
parameter in the dialog box.
For more details on how to operate the network configuration interface, please refer to section
11.1.1 of the help file of CANopen Builder software.