3 recommended fields of application, Recommended fields of application -3 – YSI IFL 700 IQ User Manual
Page 7

IFL 70x IQ
Overview
1 - 3
ba76129e01
10/2012
Fig. 1-3
Principle of the ultrasonic measurement
Wiper (cleaning system)
The IFL 700 IQ sensor has a mechanical wiper that effectively cleans
gas bubbles and dirt off the ultrasonic transducer. The wiper operates
contactless and is maintenance-free and wear-free.
1.3
Recommended fields of application
Sludge level control and monitoring in waste water treatment.
1
Transmitted ultrasonic waves
2
Echo reflected by the sludge blanket (short reflection interval)
3
Echo reflected by the bottom area (long reflection interval)
Sludge blanket level
1
3
2
Ultrasonic
transducer
Bottom
Detailed information on the subject of sludge level mea-
surement is given for example in the DWA information
sheet no. 256 "Prozessmesstechnik auf Kläranlagen, Teil
8: Messeinrichtungen zur Bestimmung des Schlammspie-
gels" (Process measuring technique at wastewater treat-
ment plants, part 8: Instrumentation for determination of the
sludge level".