Hp service pack for proliant, Hp smart update manager, Hp rom-based setup utility – HP ProLiant MicroServer Gen8 User Manual

Page 67: Using rbsu, Hp rom-based setup, Utility

Advertising
background image

Software and configuration utilities 67

HP Service Pack for ProLiant

SPP is a comprehensive systems software (drivers and firmware) solution delivered as a single ISO file with
major server releases. This solution uses HP SUM as the deployment tool and is tested on all supported HP

ProLiant servers including HP ProLiant Gen8 servers.
SPP can be used in an online mode on a Windows or Linux hosted operating system, or in an offline mode

where the server is booted to an operating system included on the ISO file so that the server can be updated
automatically with no user interaction or updated in interactive mode.
For more information or to download SPP, see one of the following pages on the HP website:

HP Service Pack for ProLiant download page (

http://www.hp.com/go/spp

)

HP Systems and Server Software Management page (

http://www.hp.com/go/SmartUpdate

)

HP Smart Update Manager

HP SUM is a product used to install and update firmware, drivers, and systems software on HP ProLiant

servers. HP SUM provides a GUI and a command-line scriptable interface for deployment of systems software
for single or one-to-many HP ProLiant servers and network-based targets, such as iLOs, OAs, and VC Ethernet

and Fibre Channel modules.
For more information about HP SUM, see the product page on the HP website

(

http://www.hp.com/go/hpsum

).

To download HP SUM, see the HP website (

http://www.hp.com/go/hpsum/download

).

To access the HP Smart Update Manager User Guide, see the HP SUM Information Library

(

http://www.hp.com/go/hpsum/documentation

).

HP ROM-Based Setup Utility

RBSU is a configuration utility embedded in HP ProLiant servers that performs a wide range of configuration

activities that can include the following:

Configuring system devices and installed options

Enabling and disabling system features

Displaying system information

Selecting the primary boot controller

Configuring memory options

Language selection

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or

the HP RBSU Information Library (

http://www.hp.com/go/rbsu/docs

).

Using RBSU

To use RBSU, use the following keys:

To access RBSU, press the F9 key during power-up when prompted.

To navigate the menu system, use the arrow keys.

Advertising