Technical data, Connections, Dimensions – La Cornue CornuFé 44 User Manual

Page 43: Ratings, Oven efficiencies

Advertising
background image

41

11. Technical Data

INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity. Remove the drawer

(see Overview > Storage for details).
COUNTRY OF DESTINATION: USA, Canada.

Connections

Electric

240 V 60 Hz

Gas

½” NPT at rear left-hand side

Dimensions

Overall height

minimum 35

15

/

16

” (91cm)

maximum 36

7

/

8

” (93.7cm)

Overall width

35½” (90cm); see ‘Positioning of Cooker’.

Overall depth

28

5

/

8

” (720 mm)

Minimum space for cooktop

31½” (800 mm)

Ratings

Oven
Fan element

2.5 kW

Top element

1.2 kW

Browning element

1.15 kW

Bottom element

1.0 kW

Gas Hob

Bypass

Screw*

Natural Gas 4” WC

Propane Gas 10” WC

Input

Orifice

Input

Orifice

Centre burners

49

17,500 btu/hr

205

17,500 btu/hr

118

Larger burners

38

12,000 btu/hr

150

12,000 btu/hr

99

Right-hand front burner

31

6,000 btu/hr

112

6,000 btu/hr

68

* The valves in this range are fitted with adjustable bypass screws. The range is supplied with the bypass screws set for Natural

gas. For LPG conversion the bypass screws must be screwed all the way down.

Oven Efficiencies

Ovens

Left-hand

Multi-function

Right-hand

Convection

Maximum total electric load 240 V

2.5 kW

2.5 kW

Energy efficiency class on a scale of A (more efficient) to G (less efficient)

A

A

Energy consumption based on standard load

0.95 kWh

0.90 kWh

Usable volume (cubic feet)

2.5

2.5

Size

Large

Large

Time to cook standard load

42.5 minutes

40.5 minutes

Maximum total electric load 240 V (including oven fans, lights, etc.): = 5.1 kW, 22 A.
Note:
The maximum input at any time is given as the fanned grill, which is all top elements and the fan.

ArtNo280-0090 Drawer Cavity & Badges