Library logs, View library logs screen – Dell PowerVault TL1000 User Manual

Page 103

Advertising
background image

Library logs

Select Service Library > View Library Logs to display a log history summary of
errors that occurred.

The error log is displayed with sense data information. The summary can be
filtered to display errors with specific sense data code types.

Click Refresh to read the log of errors from the tape library. You can select an error
in the Index List panel to display data specific to that error in the Detail panel.

The information that is displayed for the error comprises:

v

Index number of the error

v

Date and time the error occurred

v

Error code

v

Description of the error

There are two types of error data that are displayed in the library log with
different Code attributes:

v

Library/Drive sense data (Sense key/ASC/ASCQ)
For example, a 5/3B/0D error states that an illegal request was initiated that
resulted in a “medium destination element full” error that is reported by the
library. Selecting log entry 012 provides detailed sense data for this failure.
Information about sense data is listed in Appendix C, “Sense data,” on page C-1.

v

Library/Drive error code ([Code])
For example, in log entry 010, a [0222] error states that the library cannot eject
medium because drive is in state of Prevent Media Removal. Information about
errors and action to resolve the problem are listed in Appendix A, “Error codes,”
on page A-1.

a29z0131

Figure 4-49. View Library Logs screen

Chapter 4. Operations

4-35