Sanitary So^iiptdr Top Seal
When microwave oven is placed on a counter top,
its base must be sealed in accordance with
N.S.F. Standards as per the following
instructions.
1. Microwave oven should be located on a level
counter top surface. Complete the electrical
connections.
2. Thoroughly clean and sanitize the microwave oven
bottom perimeter and the counter top area around
the microwave oven perimeter.
3. Remove the Air Filter from the front of the oven
before applying silicone.
4. Lay generous bead of silicone seal around the
entire perimeter of the base of each microwave
oven unit.
5. Smooth the silicone seal into the crevice with finger
or tool to provide a cove seal.
Note: DO NOT FORGET to re-install the Air Filter
after applying silicone.
Counter Top
Care
Oven
1. Remove the plug from the electrical socket before
cleaning.
2. Keep the inside of the oven clean. If pieces of food
or spilled liquids stick to the oven walls, or between
door seal and door surface, they will absorb
microwaves and may cause arcing or sparks. Wipe
up all spills with a damp cloth. Kitchen detergent or
an approved sanitizing solution may be used if the
oven gets very dirty. Do not use harsh detergents or
abrasives.
3. The outside surface of this microwave oven should
be cleaned with soap and water, then dried. Make
sure that water does not get into the back
ventilation or control panel opening since this can
damage the unit.
4. The window of the door should be washed with
very mild soap and water. Be sure to use soft
product. Never use window clearer. The front door
can be scratched by harsh soap or cleaners.
REPLACEMENT OF THE
OVEN LAMP BULB
If the Oven Lamp burns out, it can be replaced by
following these directions.
1. Unplug the oven.
2. Unscrew the Oven Lamp Cover which is located on
the left side of the cabinet.
3. Replace the old bulb with a new one.
(use 230 V - 250 V / 20 W BULB)
4. Reinstall the Oven Lamp Cover.
CAUrioN
Remove the plug from the electrical socket before
replacement of the Oven Lamp Bulb.
CLEANING THE AIR FILTER
Clean the Air Filters occasionally according to the
following instructions. Problems may occur with the
oven if the filters become clogged with dirt or dust.*
1. Remove the right Air Filter from the front bottom
skirt by pulling the Right Pop Pin straight out. Then
siide the filter to the right and lift it off the post at
the center. Remove the left Air Filter the same as
right one.
2. Wash the filters with soap and water.
3. To replace, align the filter with the center post, and
holding the front of the Pop Pin forward, insert the
back of the pin into its hole. Press the front of the
pin and it will pop into place. Be sure to replace the
air filters before using this oven.
If the Air Filter becomes clogged with dust or
grease this will cause an overheat problem on the
oven.
-
14
-