Diagnostic Codes
CMW
222
INNER ROT SPD
inner rotation position
sensor not changing
dither compensation is
blocked
non-
essential
223
ROTATE SPD
rotation position sensor not
changing
full auto pipe is blocked
non-
essential
231
PIPELOADER
RSW
more than two pipeloader
rocker switches are active
pipeloader functions are
blocked
essential
233
DRL/DRV SW
both drill (in seat) and drive
(tether) operator presence
inputs are present
unit will not drill or drive; will
recover if condition clears
essential
234
ADDP/REMP SW
add pipe and remove pipe
inputs both on
add pipe and remove pipe
are blocked
non-
essential
235
TH F/R HSW
front and rear home switch
inputs both on
add pipe and remove pipe
are blocked
non-
essential
241
SHUTTLE RESP
shuttles not responding
correctly
add pipe or remove pipe is
aborted and code is stored
non-
essential
251
FLOAT ZERO
float sensor is reading too
low
assisted makeup is blocked
and code is stored
non-
essential
252
FLOAT RANGE
float sensor is reading out of
range
assisted makeup is blocked
and code is stored
non-
essential
253
A2D SYNCH
questionable voltage
reading on controller circuit
board
code is stored
non-
essential
254
SETUP TABLE
error reading setup table
information
add pipe and remove pipe
are blocked
essential
255
MISC CODE
undefinable diagnostic code
reported
code is stored
non-
essential
412
START MSG
normal entry into diagnostic
mode for Information Center
code is not stored
413
3VOLT POWER
3V power error in
Information Center
414
5VOLT OUTPUT
5V output error in
Information Center
415
MSC OUTPUT
misc output error in
Information Center
code is stored in Information
Center
416
BACKLIGHT PWR
backlight power error
backlight may not function
correctly
417
LCD -20V PWR
LCD -20V power error
LCD may not function
correctly
Code
Display
Condition
Result
Severity