Reclaim antifreeze, Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual
Page 192
Advertising
JT30 /JT30 All Terrain Operator’s Manual
Complete the Job - 192
Antifreeze Drilling Unit
CMW
Reclaim Antifreeze
1.
Hold hose on antifreeze reclaimer over top of antifreeze tank.
2.
Open valve on reclaimer (shown).
3.
Connect drilling fluid transfer hose from
tanks to drilling fluid pump inlet.
4.
Close valve below antifreeze tank.
5.
Start unit and run at low throttle.
6.
Turn drilling fluid pump on low speed.
7.
Turn drilling fluid pump off when drilling
fluid comes out of reclaimer hose.
8.
Remove antifreeze reclaimer.
IMPORTANT: Antifreeze can be removed
from antifreeze tank and disposed of
properly or it can be reused until it is too
diluted with drilling fluid to protect against
freezing.
j34om015w.eps
Advertising
This manual is related to the following products: