12

CAUTION! Ensure

location grooves are free

from dirt and debris.

3. Refitting the exhaust

diffusers is carried out

by sliding ONE diffuser

at a time onto the case,

once both diffusers

are located on the

case, squeeze the two

diffusers together until

you hear an audible

“click”.

Note: The removal

and refitting of the small exhaust diffusers is carried out in

exactly the same way as the large exhaust diffusers. If the

exhaust diffusers do not securely clip together then they may

become detached and lost. (If required, exhaust diffusers may be

purchased separately).

WARNING: Do not attempt to use tools to remove or attach the

exhaust diffusers. After the removal of the exhaust diffusers, care

must be taken to prevent damage to the exhaust valve. Do not attempt

to poke, pull or touch the exhaust valve or surrounding area with

any tools. If damage to this part or surrounding area occurs then this

could cause your regulator to leak, causing serious malfunction or

even personal injury. Care must be taken when securing alternative

sets of diffusers, do not apply excessive force as damage may occur

to the diffusers, exhaust valve or surrounding area.

Shaded area indicates exhaust

valve and surrounding area.

Regulator Owner’s Manual

............................................................................................

LOCATE

SLIDE

Showing
Compact
Exhaust Option

Shaded area

indicates

exhaust

valve and

surrounding

area.