14

INSTALLATION

CAVITY DIMENSIONS

BE1-48R

BE1-36R

Inches (mm)

Inches (mm)

A

Maximum height of enclosure shell

35 1/2" (902)

35 1/2" (902)

B

Depth of enclosure shell

22 3/4" (578)

22 3/4" (578)

C

Minimum depth for hood swing

3 3/4" (95)

3 3/4" (95)

D

Width of enclosure cavity

51 5/8" (1318)

40 1/2" (1029)

E

Height of enclosure cavity

11 1/8"(283)

11 1/8"(283)

f

Depth to gas supply opening

18 1/2"(464)

18 1/2"(464)

G

Height to base of vents

1" (25)

1" (25)

H

Height of opening for access doors/drawers

20" (508)

20" (508)

I

Width of opening for access doors/drawers

46" (1168)

34" (864)

ACCESS DOORS
MODEL NUMBER

ACCESS DRAWERS
MODEL NUMBER

CAVITY WIDTH

CAVITY HEIGHT

Inches (mm)

Inches (mm)

ADN1-20x48

ADR2-48

46" (1168)

20" (508)

ADN1-20x36

ADR2-36

34" (864)

20" (508)

ADN1-20x30

ADR2-30

28" (711)

20" (508)

ADN1-20x24

ADR2-24

22" (559)

20" (508)

D

E

H

I

G

F

A

B

C

Built-in Construction Details

Standard layout for cavity including insulated jacket

Note: vents are to be located at the left,
right and rear of the enclosure. Minimum
size of all vents is 10x10" (645mm x 645mm)

Note: the cut-out of each
corner should be a 90°angle
in order for the access doors/
drawers to fit properly.

Note: 4x4” (102mm x 102mm)
opening for gas supply line

FIG. 06

To order access drawers or doors, please visit www.dcsappliances.com for further details.