Units and probe type, Probe fault, Set/view units – Mercury PR0091 User Manual

Page 9

Advertising
background image

Mercury 6-5 Stat – Installation & User Guide


Parameter table for 5 Channel Thermostat Continued.......

Number Parameter

Range

Step

Units

Default

P79

Tuesday On Time 1

00:00 to 23:59

00:01

hh:mm

08:00

P80

Tuesday Off Time 1

00:00 to 23:59

00:01

hh:mm

20:00

P81

Tuesday On Time 2

00:00 to 23:59

00:01

hh:mm

08:00

P82

Tuesday Off Time 2

00:00 to 23:59

00:01

hh:mm

20:00

P83

Wednesday On Time 1

00:00 to 23:59

00:01

hh:mm

08:00

P84

Wednesday Off Time 1

00:00 to 23:59

00:01

hh:mm

20:00

P85

Wednesday On Time 2

00:00 to 23:59

00:01

hh:mm

08:00

P86

Wednesday Off Time 2

00:00 to 23:59

00:01

hh:mm

20:00

P87

Thursday On Time 1

00:00 to 23:59

00:01

hh:mm

08:00

P88

Thursday Off Time 1

00:00 to 23:59

00:01

hh:mm

20:00

P89

Thursday On Time 2

00:00 to 23:59

00:01

hh:mm

08:00

P90

Thursday Off Time 2

00:00 to 23:59

00:01

hh:mm

20:00

P91

Friday On Time 1

00:00 to 23:59

00:01

hh:mm

08:00

P92

Friday Off Time 1

00:00 to 23:59

00:01

hh:mm

20:00

P93

Friday On Time 2

00:00 to 23:59

00:01

hh:mm

08:00

P94

Friday Off Time 2

00:00 to 23:59

00:01

hh:mm

20:00

P95

Saturday On Time 1

00:00 to 23:59

00:01

hh:mm

08:00

P96

Saturday Off Time 1

00:00 to 23:59

00:01

hh:mm

20:00

P97

Saturday On Time 2

00:00 to 23:59

00:01

hh:mm

08:00

P98

Saturday Off Time 2

00:00 to 23:59

00:01

hh:mm

20:00

dFLt

Factory

Defaults




Units and Probe Type

Change the probe type to: -

0 = PTC1000

o

C

Range

-42

o

C to +128

o

C

1 = PTC1000

o

F

Range

-43

o

F to +262

o

F

2 = NTC2000

o

C

Range

-37

o

C to +54

o

C

3 = NTC2000

o

F

Range

-34

o

F to +129

o

F

4 = NTC2k25

o

C

Range

-37

o

C to +54

o

C

5 = NTC2k25

o

F

Range

-34

o

F to +129

o

F



Probe Fault

If a probe fault occurs then the controller will pulse its associated relay(s) on for 5 minutes then off for 5
minutes.

Ensure that all power is



switched off before
installing or maintaining
this product

Revision 1.2

Page 9 of 21

Advertising