Goulds pumps, Phv - packaged hydrovar series, Variable speed performance curves – ITT BPHV User Manual

Page 28

Advertising
background image

28

Goulds Pumps

PHV - Packaged Hydrovar Series

VARIABLE SPEED PERFORMANCE CURVES

4SV VARIABLE SPEED CURVE
SSVB 304SS

Multi-Stage Pumps

MODEL: 4SVB 2 Stage

Hydraulic Data

Maximum Flow

Flow at Duty Point

Maximum TDH

TDH at Duty Point

NPSH

R

112 US GPM

148 feet

0

10

20

30

40

50

[US GPM]

0

0.5

[HP] -2

2

4

6

[FT]

0

10

20

[FT]

Fluid: Water, pure

Duty Chart: 3500 RPM

Head

NPSH - values

Shaft power P2

2

30 Hz

40 Hz

50 Hz

60 Hz

Application Range

30 Hz

40 Hz

50 Hz

60 Hz

2 (P2)

30 Hz

40 Hz

50 Hz

60 Hz

30

40

60

70

80

90

8

10

50

60

70

80

90

100

110

1

100

110

1.5

12

2

120

130

140

2.5

3

150

3.5

4

4.5

14

0