Intelligent Motion Systems Modular LYNX System User Manual

Page 10

Advertising
background image

1 - 10

Modular LYNX System 12.05.2003

S e c t i o n 3

M o u n t i n g t h e LY N X S y s t e m

S e c t i o n O v e r v i e w

This section covers the two basic methods of mounting the LYNX System.

!

Panel Mount.

!

DIN Rail Mounting Option.

P a n e l M o u n t

Using the panel mount option, the LYNX is designed to use #10 hardware (not included). Details such as
screw length and threads are dependent on your overall system design.

D i n R a i l M o u n t i n g O p t i o n

A DIN Rail mounting kit (IMS P/N LX-DB100-000) may be purchased as an option to your LYNX System. It
includes all the hardware necessary to mount the system to either of the following recommended DIN rails:

TS35 X 7.5 or TS35 X 15

I n c l u d e d i n t h e D I N R a i l M o u n t i n g K i t

Included in the DIN Rail Mounting Kit is the following hardware:

!

2 - IMS0065 DIN Rail Brackets

!

4 - #6 Split Lock Washer

!

4 - #6-32X7/16 L Pan Hd Machine Screws

!

4 - #6 Flat Washer .040 Thick

!

2 - #6 X .250 L Set Screw

!

1 - Instruction Sheet

M o u n t i n g t h e LY N X S y s t e m
t o a D I N R a i l

In order to install your LYNX System on a
DIN rail complete the following:

1.

Insert the two DIN rail brackets
into the slots located in the
back of the system between the
end plates and LYNX modules.
The pull-tab on the DIN rail
bracket must be on the bottom.

2.

Using the #6 hardware pro-
vided, secure the bracket to the
end plates. Figure 3.1.
Tighten to 5 - 7 lb/in.

Figure 3.1: Installing the DIN Rail Bracket

#6 Split Lock Washer

# 6-32 X 7/16 Machine
Screw (5 - 7 lb/in torque)

#6 Flat Washer

A

B

C

D

B

B

C

D

A

B

C

D

DIN Rail Bracket

Advertising