Stacking hubs, Why stack, Guidelines – Intel 220T User Manual

Page 11

Advertising
background image

9

Stacking Hubs

Why Stack?

The Express 220T and 210T hubs use the same connectors so they can be
stacked together or stacked in combination with the Express 10/100
Stackable hub. By stacking Intel hubs you can:

• increase the number of available ports, yet still treat the stack as a

single repeater.

• use a single Management Module to manage all hubs in the stack.

• use the 220T’s internal bridge so 10Mbps and 100Mbps segments can

communicate.

Guidelines

• You must use an Intel Cascade Cable to stack the hubs. Do not daisy-

chain hubs operating at 100Mbps with UTP cable.

• A stack can consist of any combination of 220T, 210T, or

Express 10/100 hubs (12- or 24-port versions).

• You can stack up to eight hubs.

• When cabled correctly, the top hub in a stack is numbered hub 1.

• If there is more than one 220T hub in a stack, only one bridge is active

at a time. The lowest numbered 220T hub is the active bridge.

• All devices at the same speed are in the same segment. For example, all

devices at 10Mbps are in one segment and all devices at 100Mbps are
in another.

Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz

Redundant Power Supply (RPS)

Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz

Redundant Power Supply (RPS)

Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz

Redundant Power Supply (RPS)

Hub 1

Hub 2

Hub 3

Intel Cascade
Cable (EE200CC)

Express 220T Hub

Intel Cascade

Cable

Can

stack

with

Express 210T Stackable Hub and
Express 10/100 Stackable Hub
(12- or 24-port versions).

+

Colls 10Mbps

Colls 100Mbps

RPS

Power

Intel Express 220T
Stackable Hub

Bridged

Managed

Enable/Disable
Bridging

Status

Class

I

Left (Orange/Green)
Orange = 10Mbps
Green = 100Mbps
Solid = Link
Blink = Activity

Right (Yellow)
Solid = Disabled
Blink = Wrong speed

1

2

3

4

5

6

7

8

9

10

11

12

10Base-T

100Base-TX

Power

Intel Express 210T
Stackable Hub

Collision

Managed

Status

Class

I

Left (Green)
Solid = Link
Blink = Activity

Right (Yellow)
Solid = Disabled
Blink = Wrong speed

Change Hub Speed

1

2

3

4

5

6

7

8

9

10

11

12

10Base-T

100Base-TX

Power

Intel Express
10/100 Stackable Hub

Collision

Managed

Status

Class

I

Left (Green)
Solid = Link
Blink = Activity

Right (Amber)
Solid = Disabled
Blink = Wrong speed

Change Hub Speed

24

23

22

19

21

20

16

17

18

10

11

12

15

14

13

8

7

6

5

4

9

1

2

3

Connect the Cacade
Cables to the hubs as
shown in the diagram.

Advertising