Ingersoll-Rand 66243-X User Manual

Ingersoll-Rand Pumps

Advertising
background image

OPERATOR’S MANUAL

66243--X

RELEASED: 7--7--90

REVISED: 6--4--10

(REV. F) IPP

INCLUDING: SERVICE KIT, TROUBLESHOOTING, PARTS LIST,

DISASSEMBLY AND ASSEMBLY

IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

CHOP--CHECK STYLE

LOWER PUMP END

ALSO COVERS 637071- XXX SERVICE KIT

1 COIL SPRING. -

4 WAVE SPRING

5 COMPOSITE SPRING W/ADJ P’KG NUT -

-

AS OF MAY 15, 1995 NO LONGER AVAILABLE

D

UHMW--PE/LEATHER STAG’D (UPPER)

LEATHER (LOWER)

-

5

PTFE(GF)/LEATHER STAG’D (UPPER)

GLASS FILLED PTFE (LOWER)

-

1 THIOKOL LEATHER -

P

UHMW--PE/PTFE STAG’D (UPPER)

UHMW--PE (LOWER)

R

PTFE/UHMW--PE STAG’D (UPPER)

PTFE (LOWER)

(PACKINGS ARE UPPER AND LOWER UNLESS NOTED)

LOWER PUMP END OPTION

DESCRIPTION CHART*

66243--XXX

PACKING MATERIAL

3 GLASS FILLED PTFE

PACKING MATERIAL

_____

PLUNGER TYPE

SPRING ARRANGEMENT

SPRING ARRANGEMENT

PLUNGER TYPE

3 HD SS W/HD CHROME PLATING

* NOT ALL MODEL COMBINATIONS ARE AVAILABLE, REFER TO PUMP MODEL MANUAL (650XXX--XXX) FOR ‘‘ACTIVE” MODELS.

C UHMW--PE

G UHMW--PE/LEATHER STAG’D

7 THREADED PLUNGER (LG MOTORS)

SERVICE KITS

Use only genuine ARO replacement parts to assure compatible-

pressure rating and longest service life.

637071--XXX for general repair of 66243--XXX Lower Pump End.

GENERAL DESCRIPTION

LOWER PUMP END

WARNING DO NOT EXCEED MAXIMUM OPERATING PRES-

SURE AS INDICATED ON PUMP MODEL PLATE

WARNING REFER TO GENERAL INFORMATION SHEET

FOR ADDITIONAL SAFETY PRECAUTlONS AND IMPORTANT

INFORMATION.

(See the pump model manual for the proper Form

No.)

This LOWER PUMP END MANUAL is one of four documents need-

ed to properly support an ARO pump model. Ref: Part A. 650XXX--

XXX--X MODEL (OPERATOR’S) MANUAL, Part B. GENERAL

INFORMATION, Part C. MOTOR (OPERATOR’S) MANUAL, Part

D. LOWER PUMP END (OPERATOR’S) MANUAL. These forms

are available from the factory if needed.

The Chop--Check design provides far easy priming of the lower foot

valve. The double acting feature is standard in all ARO industrial

pumps, material is delivered to the pump discharge outlet on both

the up and down stroke.

PUMP RATI0 X REGULATED = MAXIMUM FLUID PRESSURE

PRESSURE

The pump ratio is an expression of the relationship between the air

motor area and the lower pump end area. EXAMPLE: When 150

PSI (10.3 Bar) air pressure is supplied to the pump motor on a 3:1

ratio pump, the lower pump end will develop a maximum of 450 PSI

(31Bar)fluidpressure(atnoflow).Asthefluidcontrolisopened,the

flow rate will increase as the motor cycle rate increases to keep up

with the demand.

Operating at excessive pressures will shorten the life of the pump.

TROUBLE SHOOTING CHOP- CHECK PUMPS

Lower Pump End Problems

No material at outlet. (Pump continually cycles.)

Check material supply, disconnect or shut off the air supply and re-

plenish the material, reconnect.

Material on one stroke only. (fast downstroke.)

The lower check may not be seating in the foot valve. (See lower

pump disassembly) Remove the check from the foot valve, clean

and inspect the valve seat area. If check or foot valve are damaged,

replace.

Material on one stroke only. (fast upstroke.)

Check for worn or damaged seals. Replace the seals as necessary.

Material leakage out of the solvent cup or material appears on the

pump plunger rod.

For Models (--X5X Only). Increase the load on the packings bytight-

ening the packing nut.

Check for worn upper packings and replace them as necessary.

INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506

(800) 495-0276 FAX(800) 892-6276

© 2010

www.ingersollrandproducts.com

Advertising