When you turn on the power to the storage subsystem, the seven-segment LEDs
show 88 before the boot firmware starts to run. After the boot code starts, - - is
displayed.

When the storage subsystem is operating normally, the numeric display shows the
enclosure identification (enclosure ID) of the storage subsystem.

If an error has occurred and the Needs Attention LED is on, the numeric display
shows diagnostic information. The numeric display indicates the information is
diagnostic by illuminating an LED that appears as a decimal point between the
display numbers. The diagnostic LED tuns off when the numeric display shows the
storage subsystem enclosure ID. The numeric display shows various diagnostic
codes as the enclosures perform the startup process after each power cycle or
reset. After diagnostics are complete, the current storage subsystem enclosure ID is
displayed.

Diagnostic codes in the form of Lx or Hx, where x is a hexadecimal digit, indicate
storage subsystem state information. In general, these codes are displayed only
when the storage subsystem is in a non-operational state. The storage subsystem
might be non-operational due to a configuration problem (such as mismatched
types), or it might be non-operational due to hardware faults. If the storage
subsystem is non-operational due to system configuration, the storage subsystem
Needs Attention LED is off. If the storage subsystem is non-operational due to a
hardware fault, the storage subsystem Needs Attention LED is on. The definitions
for Lx diagnostic codes are listed in Table 17.

Table 17. Numeric display diagnostic codes

Value

Controller State

Description

L0

Suspended

Mismatched controller board
ID

L1

Suspended

Missing interconnect canister

L2

Suspended

Persistent memory errors

L3

Suspended

Persistent hardware errors

L4

Suspended

Persistent data protection
errors

L5

Suspended

ACS failure

L6

Suspended

Unsupported host card

L7

Suspended

Submodel identifier not set or
mismatched

L8

Suspended

Memory configuration error

L9

Suspended

Link speed mismatch

Seven-segment
display

Diagnostic
LED

Figure 72. Numeric display LEDs