Controls & features – Jenn-Air JXT8036ADS User Manual

Page 6

Advertising
background image

CONTROLS & FEATURES

4

CONTROLS: FILTER CLEAN INDICATOR (METAL FILTERS)

Filter Clean Reminder (Standard Metal Filters fitted)
Whether your hood is installed as an Exhaust or Purifying unit, a set of metal filters are
fitted by the factory. These Metal Filters are intended to filter out residue from cooking.
They need not be replaced on a regular basis but are required to be kept clean. The Filter Change
Reminder
function in the microprocessor will automatically indicate by a flashing
when the metal filters need to be cleaned after every 30 hrs. of use.
Filters can be cleaned by hand with non-abrasive soap or in a dishwasher. Heavily soiled
filters should also be soaked in grease cutting detergent such as Formula '409' or its equivalent,
prior to cleaning.

Filter Clean Reminder:

When flashes on display, the metal
filters installed are required to be cleaned.
This will occur after every 30 hours of use.

Re-setting Function:

Reset the Filter Clean Reminder timer when
filters are cleaned and re-installed. Press
and hold for approx. 5 seconds, the
display will appear; hold for approximately
5 seconds until on display disappears

. The Filter Clean Reminder function

is now re-set and a new 30 hours elapse
cycle is initiated.

hold 5 secs.

display from <C> to < >

display <A> flashes

Clean Filters

To Reset

Advertising