6.17. Maintenance

The APIs below are related to maintenance. These are equivalent to the features on the Maintenance page of the

WEB setting page. Refer to the instruction manual for details on the Maintenance page.

Initialization

Format

/api/param?system.status=initialize

Example of Response

system.status&200 OK

Interpretation Restore all VN-V686 settings to factory defaults. Upon doing so, all transmission services that are

in progress will be terminated. Initializing takes a few minutes. Response is returned after initializing. Do not power

off during initializing.

Allowed user admin

Firmware Update

Version upgrading is not possible using API. To do so, use the Version Upgrade feature on the Maintenance page of

the WEB setting page.

Getting Status of Auto Cleaning from VN-V686

Format

/api/param?camera.motion.pan.auto_cleaning.status

Example of Response

camera.motion.pan.auto_cleaning.status=off&200 OK

Interpretation Acquire status of auto cleaning. "on" or "off" is returned.

Allowed users admin, operator, user

Setting Auto Cleaning for VN-V686

Format

/api/param?camera.motion.pan.auto_cleaning.status=data

Example of Response

camera.motion.pan.auto_cleaning.status

&202

Accepted(camera.status=save)

Interpretation Change status of auto cleaning. Specify on or off. To save the change, use "camera.status=save"

API.

Allowed user admin

Getting Time of Auto Cleaning from VN-V686

Format

/api/param?camera.motion.pan.auto_cleaning.time

Example of Response

camera.motion.pan.auto_cleaning.time=235959&200 OK

Interpretation Acquire time of auto cleaning. Time is returned in format of hhmmss.