Optional Wall Thermostat or
Remote Control

When installing a wall mounted thermostat to the
Allagash it must be 750 millivolt DC two-wire circuit
thermostat. The thermostat should be placed in the
same room as the heater, typically 5’ off the floor.
Avoid drafty areas or any area that may effect the
accuracy of the thermostat.

The thermostat should be connected to the

Allagash using a minimum of 16 gauge wire with a
maximum length of 35 feet of wire.

Connect the two thermostat wire leads to the

two lower terminals on the terminal block located
directly above the ignitor button. Do not overtighten
the connections. IT IS NOT NECESSARY TO DISCON-
NECT ANY OTHER WIRES. See Figure 23.

For the thermostat to work the On/Off/T-Stat

switch on the back of the stove must be in the T-stat
position, and the pilot light must be running, for it is
the power source for the thermostat.

At the thermostat the two wires should be

connected to the two connections screws on the
thermostat base plate per the manufacturer’s
instructions.

Remote Control

The remote receiver should be wired to the terminal
block the same as the thermostat. See the instruc-
tions above.

CAUTION:

LABEL ALL WIRES PRIOR TO

DISCONNECTION WHEN SERVICING

THE CONTROLS. WIRING ERRORS

CAN CAUSE IMPROPER AND

DANGEROUS OPERATION. ALWAYS

VERIFY PROPER OPERATION AFTER

SERVICING THE APPLIANCE.

Figure 22. Attaching the blower wire harness.

Snapstat

(attached to

blower bracket)

Wire Harness

Plug

BLOWER

HI/LO

SWITCH

Figure 23. Wiring Diagram / Remote or Thermostat

18

TERMINAL

BLOCK

VALVE

THERMOPILE

ROCKER

SWITCH

ON

OFF

STAT

OPTIONAL

THERMOSTAT

or

REMOTE

CONTROL

TH

TP
TH

TP

Advertising