2 typical field wiring diagram – Johnson Controls ACPU024 THRU 060 User Manual

Page 19

Advertising
background image

279815-PTG-D-0408

Johnson Controls Unitary Products

19

FIGURE 2 - TYPICAL FIELD WIRING DIAGRAM

REFER TO ELECTRICAL DATA

TABLES TO SIZE THE DIS-

CONNECT SWITCH, WIRING &

OVERCURRENT PROTECTION

REFER TO ELECTRICAL DATA

TABLES TO SIZE THE DIS-

CONNECT SWITCH, WIRING &

OVERCURRENT PROTECTION

POWER WIRING

24 VOLT TRANSFORMER

UNIT TERMINAL STRIP

THERMOSTAT

NOTE:
HEAT ANTICIPATOR SHOULD BE SET
AT 0.25 AMPS FOR ALL MODELS.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper operation after servicing.

PROGRAMMABLE

THERMOSTAT ONLY

** = Minimum wire size of 18 AWG

wire should be used for all field
installed 24 volt wire.

**

* = Only required on units with

supplemental electric heat.

*

*

CONTROL WIRING