4-4 SAVING AND CALLING UP MENU SWITCH SETTINGS

4 MENU SWITCH SETTING

The set menu switch data can be saved and called up with the 00A MENU SETTING item on the top menu
display.
If you’re going to use the current menu switch setting again later, you can store it in the user memory area. Then,
if the setting is changed, you can restore it simply by calling the stored user data.
It is also possible to restore the initial factory settings.The menu switch setting can be saved in USER-1 SAVE,
USER-2 SAVE or USER-3 SAVE .

Top menu display

Set value

Item No.

[Counter display]

[On-screen display]

300: DIRECT EJECT

ON

301:DIRECT SEARCH

ON

302:BACK SPACE

ON

307:PAUSE/STILL/STP TIME

311:AUTO PLAY

OFF

Menu switch setting display

300: DIRECT EJECT

OFF

301:DIRECT SEARCH

ON

302:BACK SPACE

ON

307:PAUSE/STILL/STP TIME

311:AUTO PLAY

OFF

300: DIRECT EJECT

ON

301:DIRECT SEARCH

ON

302:BACK SPACE

ON

307:PAUSE/STILL/STP TIME

311:AUTO PLAY

OFF

LOAD

Memory

SAVE

Change

Call up

5MIN

5MIN

5MIN

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

625

Variable Motion

COMPONENT DIGITAL

[MENU] button

[HOLD] button

[SET] button

Jog dial

Operation procedure

1. Press the [MENU] button and turn the jog dial

to call up the top menu on the on-screen
display and the counter display.

2. Select 00A: MENU SETTING.

● Turn the jog dial so that 00A appears on the

counter display and 00A blinks on the on-screen
display.

3. Select the saving or calling-up function and

execute it.

When restoring the initial factory settings

● Select “INITIAL (0)” by turning the jog dial while

pressing the [SEARCH] button.

+

● Press the [HOLD] button while pressing the

[SET] button.

[

Factory settings are restored.

[

The Normal Display mode is restored.

* The fixed time data is not changed.

To call up the saved menu setting

(Recalling data stored in USER-1 SAVE )

● Select “USER-1 LOAD” by turning the jog dial

while pressing the [SEARCH] button.

+

● Press the [HOLD] button while pressing the

[SET] button.

[

The saved menu switch setting in “USER-1

SAVE” comes up.

[

The Normal Display mode is restored.
The data stored in USER-2 SAVE or USER-3
SAVE can be recalled using USER LOAD-2 or
USER-3 LOAD , respectively.

To save the current menu switch setting

(Storing data in USER-1 SAVE )

● Select “USER-1 SAVE” by turning the jog dial

while pressing the [SEARCH] button.

+

● Press the [HOLD] button while pressing the

[SET] button.

[

The current menu setting is stored in the user
memory area. The data already saved is
updated.

[

The Normal Display mode is restored.

33

D95:525/624

00A:MENU SETTING

SET+HOLD INITIAL

00B:DIRECT ACCESS

SET+HOLD>ON

00C:USER PAGE

SET+HOLD>INITIAL

00D:MENU LOCK

SET+HOLD>OFF

REC

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

STAND BY

PREROLL

M

H

F

S

SET+HOLD[POWER OFF>525

Access item

Control

Information on display

button

TOP menu SW

EJECT

TOP menu

VIDEO menu SW PLAY

Menu SW numbered
100 and 600

AUDIO menu SW

PAUSE/

Menu SW numbered

STILL

200

SERVO/SYSTEM

STANDBY Menu SW numbered

menu SW

000 and 300

TC menu SW

REW

Menu SW numbered

400

ON-SCREEN menu STOP

Menu SW numbered

SW

500

Hour meter

FF

Drum running hours

User menu SW

PREROLL Menu switch on the

user page

4-5 CALLING UP FUNCTIONAL MENU SWITCH (Direct Access Function)

4 MENU SWITCH SETTING

The Direct Access facility groups menu switches into major functionally related groups such as SERVO and
VIDEO for easier access. These groups can be called up directly on the menu display. Hour meter data and User
Page menu switches can also be accessed this way.
The Direct Access function can be turned on or off with 00B DIRECT ACCESS on the top menu display.

Enabling the Direct Access function

Procedure

Setting

00B

Counter display

Page down function
When menu switches for a function are shown on
more than one screen, you can display the menu
screen by group with the Direct Access function.
Then, each time the operation button correspond-
ing to the same Direct Access function is pressed,
the menu screens in the group can be advanced
one screen at a time (page down function).
(e.g.) When the [PLAY] button is pressed with the
Direct Access function set to “ON”, the top screen
of menu switch #100 is shown. When the [PLAY]
button is pressed again, the next menu screen is
shown.

• If the group consists of one screen, the page

down function cannot be used.

1. Press the [MENU] button and turn the jog dial

to call up the top menu on the on-screen
display and the counter display.

2. Turn the jog dial and select “00B DIRECT

ACCESS”.

● Turn the jog dial so that “00B” appears on the

counter display and “00B” blinks on the on-
screen display.

3. Select “ON (1)” by turning the jog dial while

pressing the [SEARCH] button.

4. Press the [HOLD] button while pressing the

[SET] button.
The Direct Access function is set to ON.

[

The Normal Display mode is restored.

To disable Direct Access, select “OFF (0)” by
turning the jog dial while pressing the
[SEARCH] button, then press the [HOLD]
button while pressing the [SET] button.

Using the Direct Access function.

● Make sure the Direct Access function is set to

“ON”.

1. Press the [MENU] button to call up the menu

setting display.

2. Press the corresponding front panel control

button, depending on the item. (Refer to the
table on the left.)
[

The starting item is shown on the counter
display and the first data appears on the on-
screen display, depending on what has been
selected.
Move the items by turning the jog dial.

Front panel operation buttons

On-screen display

The labels under the front panel control buttons
indicate the functions that can be called up with
the Direct Access facility.

Advertising