1 Starting the communication: connection command (!00BCN1Cr)

3 Selecting the Input A (!00BINACr)

5 Terminating the communication: termination command

(!00BCN0Cr)

6 Monitor’s status (@00BOKCr)

4 Monitor’s status (@00BOKCr)

2 Monitor’s status (@00BOKCr)

34

How to Use External Control

(cont.)

Using the serial communication

You can control the monitor from external control equipment (a personal computer or a dedicated controller) via the RS-485
or RS-232C terminal.

<Communication specifications>

Input terminal

Cable

Terminal specification

Communication specifications

RS-485

A straight LAN cable

See page 35.

Baud Rate:

4800 bps

Data Bits:

8 bits

Parity: No parity
Stop Bits:

1 bit

Flow Control: No control
Communication Code: ASCII Code

RS-232C

A straight cable with a RS-232C
connector (male for the monitor,
female for the external control
equipment)

<Command outline>
When the monitor is turned on, the external control is not ready.
• To start communication, send the connection command from the external control equipment.
• To terminate the communication, send the termination command from the external control equipment.

Example of communication procedures:

• Commands starting with “!” are operation commands from the external control equipment. For details, see “Command list” on the next page.
• Commands starting with “@” are status returns from the monitor.

External control
equipment

Monitor