9 multi roi mode (multi region of, Mode and functions matrix, At-140ge – JAI AT-140GE User Manual

Page 52

Advertising
background image

AT-140GE

- 50 -

9.7.9 Multi ROI mode (Multi Region of Interest)
In this trigger mode, up to 5 ROIs located on one image can be output by one trigger input.
By using this mode, the data stream can be smaller. Each ROI can be overlapped.

Please note that if the accumulated data size is bigger than the data size of 1 frame, the
frame rate will be reduced.
As explained in section 9.3.3, a partial scan mode is associated with ROI and in the case of
figure 51, the start line of ROI 2 and the end line of ROI 4 would define a partial scan area.










Fig. 51 Multi ROI conceptual drawing

9.8. Mode and functions matrix

ID

Mode

Shutter

Programmable/

Exposure Abs

Auto
shutter

V
Binning

Partial

scan

Smear

less

Multi

ROI

LVAL

Sync/

Async

Auto Iris

output

0x00 Continuous

Ч

Ч

---

0x01

EPS

×

Auto

×

0x02

PWC

---

×

Auto

×

0x04

RCT

Async

only

0x09

Sequential

EPS

Ч

Ч

Auto

×

0x11

EPS

Delayed

readout

Ч

Ч

Auto

×

0x12

PWC

Delayed

Readout

---

Ч

Ч

Auto

×

Note: 1. Trigger mode can be set by writing ID value in register 0xA040.
2. In trigger modes from ID 0x09 to ID 0x12, if trigger mode is changed, set “Acquisition Stop”

and then set continuous mode(ID 0x00) first and change to required trigger mode. For
instance, it is not possible to change directly from ID 0x09 sequential EPS mode to 0x11 EPS
delayed readout mode.

ROI
1

ROI 2

ROI
3

ROI 4

ROI 5


Partial scan area