Wiring, Power and outputs, Ground terminal (gnd) – Jensen XA4150 User Manual

Page 4: Fuses, Xa4150

Advertising
background image

4

®

XA4150

Wiring

Power and Outputs

Remote Terminal (RMT +12V)

Power Terminal (BATT +12V)

Connect directly to the vehicle battery+
terminal with 8 gauge wire (minimum).

Ground Terminal (GND)

Connect to a good chassis ground. The ground
connection should be to clean, unpainted metal
to provide a good electrical connection.

Connect the radio power antenna lead from
the receiver to the amplifier remote (RMT)
terminal. This turns the amplifier on whenever
the receiver is turned on. If a power antenna
lead is not available, connect this wire to the
radio or accessory fuse.

Use only two 25 amp
blade-type fuses.

Fuses

25A

FUSE

Spade

Connector

8 Gauge

Wire

To Battery+

Terminal

50 amp Fuse

or Circuit Breaker

Battery

Terminal

Adapter

Install as close

to the battery

as possible

Not Supplied

RMT

GND

+ 12V

Ring

Connector

Drill 1/8" hole

in chassis

sheet metal

Sheet Metal

Screw

(supplied)

Spade

Connector

8 Gauge

Wire

RMT

GND

+ 12V

To Receiver

Power

Antenna Lead

Butt

Connector

(not supplied)

Spade

Connector

8 Gauge

Wire

RMT

GND

+ 12V

RMT

POWER

GND

+ 12V

SPEAKER

A-CH

B-CH

C-CH

D-CH

+

+

+

+

25A

25A

FUSE

5314Eamp.p65

4/10/99, 7:08 PM

4