Blower function – Jotul GI 425 DV User Manual

Page 25

Advertising
background image

25

Figure 30a. GI425 Controls - Burner Control and
Blower Switch.

ON

OFF

STAT

HI

OFF

LO

Burner Control

Blower Function

and

Speed Control

Manual

Thermostatic

or

Remote Control

Blower Conrol

Blower Function

The blower is controlled by a heat-activated switch
(snapstat) that will ONLY function if the blower
control switch is in either the HI or LOW setting. The
blower will not operate until the sensor reaches
180°F. This will take 15-20 minutes in most installa-
tions.

Conversely, once the burner is off, the blower will

continue to operate until the snapstat cools down to
140°F and shuts off power to the blower.

If the blower is not needed, place the blower

control switch in the OFF position and the snapstat
will not function.

CAUTION: Always unplug the Blower when

performing any routine service to the GI425 gas
fireplace.