Api for acquiring/changing parameters of vn-e4, Explanatory notes – JVC 4ch Network Encoder VN-E4 User Manual

Page 18

Advertising
background image

18

5. API for Acquiring/Changing Parameters of VN-E4 _

5.1. Explanatory Notes

This section provides a description of API for acquiring/changing the parameters of VN-E4. Make use of the API explained in this section in
the way as mentioned in Section 4.

(1) Acquiring parameters

● Specify API in GET line according to the format below when acquiring a parameter from VN-E4.

/api/param?ParamA.ParamB.ParamC

It is possible to acquire multiple parameters at a time. Parameters are segmented using &. Do not insert
space before and after &.

/api/param?ParamA.ParamB.ParamC&ParamA.ParamD.ParamE

The upper limit of this character string is 1024 bytes. The maximum number of parameters that can be
acquired at a time is 5.

● When acquisition is successfully completed, values will be shown in the Body of the response, followed by

returning a "&200 OK" response.

Example:

ParamA.ParamB.ParamC=Data&200 OK

When an error occurs, an error code will be returned instead of indicating a value in the Body of the
response.
Example:

ParamA.ParamB.ParamC&401 Unauthorized

When multiple acquirings are performed at one time, a response will be returned for each setting.

ParamA.ParamB.ParamC&200 OK<CRLF>

ParamA.ParamB.ParamD&200 OK<CRLF>

(2) Setting parameters

● Specify API in GET according to the format below when setting a parameter for VN-E4.

/api/param?ParamA.ParamB.ParamC=Data

Parameter values are indicated using =. Do not insert space before and after =.

It is possible to perform multiple settings at a time. Parameters are segmented using &. Do not insert space
before and after &.

/api/param?ParamA.ParamB.ParamC=Data&ParamA.ParamB.ParamD=Data

The upper limit of this character string is 1024 bytes. The maximum number of parameters that can be set at
a time is 5.

● Response will be in the following format.

ParamA.ParamB.ParamC&200 OK

An error code will be returned when setting is not properly performed. Example:

ParamA.ParamB.ParamC&401 Unauthorized

When multiple settings are performed at one time, a response will be returned for each setting.

ParamA.ParamB.ParamC&200 OK<CRLF>

ParamA.ParamB.ParamD&200 OK<CRLF>

5. AP

5.1. Explanatory Notes

Advertising