Command Usage

See “Displaying Switch Hardware/Software Versions” on
page -28 fo
r detailed information on software items. The
meaning of hardware items are as follows:

Serial Number – Serial number of the main board.
Hardware Version – Hardware version of the main board.

Number of Ports – Number of ports on this switch

Module Type – The module type installed in this switch
Main Power Status – Power status for the switch.

Example

Authentication Commands

You can configure this switch to authenticate users logging into
the system for management access using local or RADIUS
authentication methods.

Remote Authentication Dial-in User Service (RADIUS) is a logon
authentication protocol that uses software running on a central
server to control access to RADIUS-aware devices on the network.
An authentication server contains a database of multiple user
name/password pairs with associated privilege levels for each user
that requires management access to a switch.

Console#show version
Unit1

Serial number

:12345

Hardware version

:012

Module A type

:not present

Module B type

:not present

Number of ports

:26

Main power status

:up

Agent(master)

Unit id

:1

Loader version

:0.0.0.2

Boot rom version

:0.0.0.6

Operation code version :1.0.0.5

Console#