4.2 Display and control parameters on remote control panel (optional)

4.3 Light Emitting Diodes (LED)

LED

Marking

LED lit

LED blinks

1 AC

IN

Voltage
corresponding to
self-adjusted
values is at the AC
IN input.

A voltage outside the self-adjusted
values is at the AC IN input, or the XP-
COMPACT is in synchronization
phases

2 CHARGER

Battery charger is
working

The battery charger is locked OFF
(see chap. 4.7) or provisory out of
order. In that last case it will restart
within 10 seconds

3

SOLAR

CHARGE

Connected solar
modules are
delivering energy

4 Program

Program mode for
Aux. Contact

5

Contact

active

Auxiliary Contact is
activated

6

Contact

manual

Aux. Cont.
manually activated

7 TRANSFER

Transfer system is
active. In- coming
voltage is being
sent directly to AC
OUT outlet

Transfer (bypass) is disabled (see
chap. 4.8)

8 AC

OUT

There is a voltage
at the AC OUT
outlet

The Inverter is in Standby-Mode

9 INVERTER

Inverter

is

working

Forced Inverter Mode (see chap. 4.6)