6 of 20, Equipment, Control panel (cp) – Security Systems TS2000 User Manual

Page 6: Power supply

Advertising
background image

Equipment

System Specification

Supply Voltage:

240V + or - 10% 30W 50 Hz

Battery:

12V 6Ah

Zones:

128 maximum

Outputs:

128 remote 8 local maximum

Unit Dimensions: CP

L 395 x W 280 x D 100mm

(boxed) NU/WCU

L 145 x W 85 x D 50mm

REM

L 220 x W 145 x D 40mm

Unit Weights:

CP

4 kg

NU/WCU

220 g

REM

430 g

Environment:

0 - 40

°

C 95% RH n.c.

Control Panel (CP)

The CP comprises electronic units inside a white

polycarbonate lid and a steel base which are factory

assembled to hinge on the left but which may be

reversed if required.
The Base Unit contains the mains input terminals and a

mains transformer. Space is provided for a battery and

also for a Digital Communicator. Cable entry points are

provided as follows:

1.

Four 20mm knockouts top and bottom;

2.

Two Holes for plastic trunking fitted with plastic inserts

top and bottom;

3.

13mm round knockouts fitted in the plastic inserts;

4.

Four 20 mm round holes in the back.

The lid unit contains the Main Control printed circuit

board (pcb) and the Power Supply pcb which are

secured on posts and on which are fitted terminals for

external connections. Option Boards (SIB and PIB) may

also be fitted to the main board.
Under normal conditions the unit can be positioned at

any location as access will only be required for

maintenance.

Power Supply

The CP is fitted with the system combined Power Supply

and Battery Charger Unit and a battery which will provide

power during a mains failure. Power arrangements are

as follows:
1 Mains input 240V +/- 10%
2 Battery 12V 6Ah Sealed Lead Acid rechargeable

type which is normally float charged at about 13.6V;
3. System regulated supply 12V with a maximum

output of 1.5A. The internal supply is load

protected and the external supply fused;

4. System internal 5V supply;
5. Standby operation during a mains failure depends

upon battery size and the size of the system.

Current consumption may be calculated as

follows:

(a)

CP: normal 150mA; alarm 500mA;

(b)

Each NU (with 4 circuits connected): normal

33mA;

(c)

Each REM (with 4 circuits connected): normal

33mA;

(d)

Each NU/REM in alarm - load depends upon

outputs used;

6 Power supply fault monitoring is for loss of mains

supply, low system supply voltage and low battery

voltage;

7 Fuses are fitted on the PSU as follows:

(a) F1: 1A QB for low voltage a.c. input;
(b) F2: 2A QB for 12V dc external output;

8 In-line Fuseholder: 1A QB for Network 12V supply;
9 A 1A fused terminal block is fitted for the mains

input.

TS2000

6 of 20

496529 Issue A