1.12 This Instant Power™ employs parts, such as switches and circuit breakers, that tend to

produce arcs and sparks. If used in a garage, locate this Instant Power™ 18 inches (46

cm) or more above floor level.

2.

PERSONAL PRECAUTIONS

RISK OF EXPLOSIVE GASES. A SPARK NEAR

THE BATTERY MAY CAUSE A BATTERY

EXPLOSION. TO REDUCE THE RISK OF A

SPARK NEAR THE BATTERY:
2.1

NEVER smoke or allow a spark or flame in

the vicinity of a battery or engine.

2.2

Remove personal metal items such as rings, bracelets, necklaces and watches when

working with a lead-acid battery. A lead-acid battery can produce a short-circuit current

high enough to weld a ring or the like to metal, causing a severe burn.

2.3

Be extra cautious, to reduce the risk of dropping a metal tool onto the battery. It might

spark or short-circuit the battery or other electrical part that may cause an explosion.

2.4

Do not permit the internal battery of the Instant Power™ to freeze. Never charge a

frozen battery.

2.5

To prevent sparking, NEVER allow clips to touch together or contact the same piece

of metal.

2.6

Consider having someone nearby to come to your aid when you work near a

lead-acid battery.

2.7

Have plenty of fresh water and soap nearby in case battery acid contacts your skin,

clothing or eyes.

2.8

Wear complete eye and body protection, including safety goggles and protective

clothing. Avoid touching your eyes while working near the battery.

2.9

If battery acid contacts your skin or clothing, immediately wash the area with soap and

water. If acid enters your eye, immediately flood the eye with cold running water for at

least 10 minutes and get medical attention right away.

2.10 If battery acid is accidentally swallowed, drink milk, the whites of eggs or water. DO NOT

induce vomiting. Seek medical attention immediately.

3.

PREPARING TO USE THE INSTANT POWER™

RISK OF ONTACT WITH BATTERY ACID. BATTERY ACID IS A

HIGHLY CORROSIVE SULFURIC ACID.
3.1

Be sure the area around the battery is well ventilated while

the Instant Power™ is being used.
3.2

Clean the battery terminals before using the Instant

Power™. During cleaning, keep airborne corrosion from coming into contact with your

eyes, nose and mouth. Use baking soda and water to neutralize the battery acid and

help eliminate airborne corrosion. Do not touch your eyes, nose or mouth.

3.3

Determine the voltage of the battery by referring to the vehicle owner’s manual and

make sure that the output voltage of the Instant Power™ is correct.

3.4

Make sure that the Instant Power™ cable clips make tight connections.

4.

CHARGER AND AC POWER CORD CONNECTIONS

RISK OF ELECTRIC SHOCK OR FIRE.
4.1

The Instant Power™ charger is for use on a nominal 120-

volt circuit. The plug must be plugged into an outlet that is properly

installed and grounded in accordance with all local codes and

ordinances. The plug pins must fit the receptacle (outlet). Do not

use with an ungrounded system.

NOTE: Pursuant to Canadian

Regulations, use of an adapter plug is not allowed in Canada. Use

of an adapter plug in the United States is not recommended and should not be used.

5.

INSTALLATION INSTRUCTIONS
Remove all cord wraps and uncoil the cables prior to using the Instant Power™.