3 technical specifications of the els tp80 – Siemens Electrical Lean Switch User Manual

Page 87

Advertising
background image

Technical Specifications

Industrial Ethernet
A5E00152007-03

87

7.3 Technical Specifications of the ELS TP80

Attachments

Attachment of DTEs or Network
Components over Twisted Pair

RJ-45 jacks with MDI-X pinning 10/100
Mbps (half/full duplex)

Electrical Data

Power Supply

24 V dc supply
(18 to 32 V dc)
safety extra-low voltage (SELV)

Power loss at DC 24 V

3.6 W

Current consumption at rated voltage

150 mA

Overcurrent protection at input

PTC resettable fuse (0.6 A / 60 V)

Permitted Cable Lengths

TP Connection

0-10 m with TP cord.
When using the FC Outlet RJ-45, the
following cable lengths are permitted:
100 m for standard cable
85 m for trailing cable
85 m for marine cable

Note
The number of ELS switches connected influences the frame propagation time.
When a frame passes through the ELS, it is delayed by the Store&Forward func-
tion of the switch.
-

with a frame length of 64 bytes by approximately 10

µs

-

with a frame length of 1500 bytes by approximately 130

µs

This means that the more ELS switches the frame passes through, the longer the
propagation time.

Aging Time

5 minutes