Specifications

The above specifications are subject to change without prior notice.

Model Name

Non-contact 3D digitizer VIVID 9i/VI-9i

Measurement Method

Triangulation, light block method

AF

Image surface AF (contrast method), Active AF

Light-Receiving lens (Inter-

changeable)

TELE

: Focal distance f=25 mm

MIDDLE: Focal distance f=14 mm
WIDE

: Focal distance f=8 mm

Object Distance Range

0.6 to 2.5 m

Scan Range

0.6 to 1.0 m (In Standard mode), 0.5 to 2.5 m (In Extended mode)

Laser Scan Method

Galvano mirror

Laser Class

Class 2 (IEC60825-1), Class 1 (FDA), Max. 30 mW, 690 nm

X Direction Input Range
(In Extended mode)

93 to 463 mm (TELE), 165 to 823 mm (MIDDLE),
299 to 1495 mm (WIDE)

Y Direction Input Range

(In Extended mode)

69 to 347 mm (TELE), 124 to 618 mm (MIDDLE),

224 to 1121 mm (WIDE)

Z Direction Input Range

(In Extended mode)

26 to 680 mm (TELE), 42 to 1100 mm (MIDDLE),

66 to 1750 mm (WIDE mode)

Accuracy

TELE

XYZ: ±0.05 mm/ ±0.10 mm

MIDDLE XYZ: ±0.10 mm/ ±0.20 mm

WIDE

XYZ: ±0.20 mm/ ±0.40 mm

(Conditions:Distance 0.6 m/ 1.0 m, KONICA MINOLTA SENSING’s standard 3D
chart, KONICA MINOLTA SENSING’s processing software, temperature 20ºC, rela-

tive humidity 65% or less)

Precision (Z,

σ)

TELE

0.008 mm/ ±0.024 mm

MIDDLE 0.016 mm/ ±0.048 mm

WIDE

0.032 mm/ ±0.096 mm

(Conditions: Distance 0.6 m/ 1.0 m, KONICA MINOLTA SENSING’s standard 2D
chart, KONICA MINOLTA SENSING’s processing software, temperature 20°C, rel-

ative humidity 65% or less)

Input Time (per scan)

2.5 sec.

Transfer Time to Host Com-

puter

Approx. 1.5 sec.

Ambient Lighting Condition

Office environment, 500 lx or less

Imaging Element

3D data

: 1/3-inch frame transfer CCD (340,000 pixels)

Color data : Common with 3D data (color separation by rotary filter)

Number of Output Pixels 3D data : 640 × 480 (640

x

460 in the HIGH QUALITY mode)

Color data : 640 × 480

Output Format

3D data: Konica Minolta format, & (STL, DXF, OBJ, ASCII points, VRML)
(Converted to 3D data by the Polygon Editing Tool Software / standard accessory)

Color data : RGB 24-bit raster scan data

Data File Size

Total 3D and color data capacity: 3.6 MB per data

Viewfinder 5.7-inch LCD (320 × 240 picture elements)

* There may be rare cases in which the point that is normally lit or unlit may break up

(dot break up); however, this will not have any influence on the scanning data.

Output Interface

SCSI II (DMA synchronous transfer)

Power

Commercial AC power, 100-240 V

(50-60Hz), rated current 0.6 A (at 100 V AC)

Dimensions

221 (W) × 412 (H) × 282 (D) mm

Mass

Approx. 15 kg (with lens attached)

Temperature / Humidity

Operating environment: 10 to 40°C (50°F to 104°F); 65% RH or less/no condensa-

tion; Installation category: II; Pollution degree: 2; Maximum altitude: 2000 m

Storage Temperature Range

0 to 40°C, 85% or less (at 35°C)/no condensation

Vivid910-hard-E.book Page 52 Monday, October 18, 2004 3:11 PM