(DHP2120) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS

(DHP2120) - IDENTIFICACIÓN DE CABLES Y DIAGRAMAS DE CABLEADO

(DHP2120) FRENCH - SCHÉMAS D'IDENTIFICATION DES FILS ET DU CÂBLAGE

WIRING DIAGRAM NOTES:
1. The DASHED lines in wiring diagram #1 are optional depending upon your system type. Single stage heat pumps will not have wires

present for the “E” or “W2” terminals. For a 2-Heat / 1-Cool system with NO Emergency heat wire, AUX heat will be connected to
“W2”. A jumper wire may be placed in between the “E” and “W2” terminals to allow Emergency Heat Mode.

2. For Heat Pumps, use either the “B” or “O” wire, NOT BOTH.
3. If “Y” and “C” wires are both present, then “C” is a common wire. Do not connect this “C” wire to your thermostat.
4. If you have a “B” wire in your system that is used as a common wire, connecting it to the “B/O” terminal on this thermostat may

damage your system and/or the thermostat.

NOTES DU DIAGRAMME DE CÂBLAGE :
1. Les lignes en TRAITS TIRÉS du diagramme de câblage 1 sont optionnelles et leur utilisation dépend de votre type de système. Les

pompes à chaleur à un étage n'ont pas de fils pour les bornes « E » ou « W2. » Pour un système à 2 chauffage / 1 refroidissement
SANS fil de chauffage d'urgence, la chaleur AUX sera branchée à « W2 ». Un fil de calier peut être placé entre les bornes « E » et
« W2 » pour permettre l'utilisation du mode de chau ffage d'urgence.

2. Pour les pompes à chaleur, utilisez soit le fil « B » ou « O », NON PAS LES DEUX.
3. Si vous avez les fils « Y » et « C », alors le « C » est le fil commun du système. Ne branchez pas ce fil « C » à votre thermostat.
4. Si vous avez un fil « B » dans votre système et si ce fil est utilisé comme fil commun, le brancher à la borne « B/O » du thermostat

pourrait endommager votre système et/ou le thermostat.

NOTAS DEL DIAGRAMA DEL CABLEADO:
1. Las líneas PUNTEADAS en el diagrama del cableado #1 son opcionales, dependiendo del tipo de sistema. Las bombas de

calefacción de una fase no contienen cables para las terminales “E” ni “W2”. Para un sistema de 2 fases de calefacción y una de
enfriamiento, NO se conecta el cable de calefacción de emergencia ni el auxiliar (AUX) en la terminal “W2”. Puede colocar un
cable para formar un puente entre las terminales “E” y “W2” y permitir un modo de calefacción de emergencia.

2. Para las bombas de calefacción, utilice el cable “B” o el cable “O”, NUNCA USE AMBOS.
3. Si tanto el cable “Y” como el “C” están presentes, entonces es más probable que el “C” sea el cable común del sistema. No

conecte el cable “C” a su termostato.

4. Si en su sistema hay un cable “B” que se utiliza como cable común, no lo conecte a la terminal “B” ni “O” del termostato, pues

podría dañar tanto su aparato como su sistema.

HEAT PUMP TERMINAL CROSS REFERENCE CHART

TABLEAU DE RÉFÉRENCE CROISÉE DE BORNE DE POMPE À CHALEUR

TABLA DE REFERENCIA PARA LA TERMINAL DE LA BOMBA DE CALEFACCIÓN

ARCO / Friedrich

ARCO / Snyder General

BARD

BARD, HP, WH, MHP, HPQ

BDP / BRYANT

CARRIER

CARRIER 5Q

CARRIER 50Q, QT382

COLEMAN

GE BAY

HEIL-QUAKER / Whirlpool

JANITROL / Goodman

LENOX TYPICAL HP6

LENOX HP8

LENOX HP9, 10

LENOX HP16, 18, 19

MAGIC CHEF PE

RHEEM / RUUD

SNYDER GENERAL H-R811

TRANE

WEATHERKING

WESCO

WESCO / ADDISON

WESTINGHOUSE H50

WESTINGHOUSE HE

WHITE RODGERS

YORK

HEAT PUMP BRAND

MARQUE DE POMPES
À CHALEUR

MARCA DE LA BOMBA
DE CALEFACCIÓN

CORRESPONDING TERMINALS

BORNES
CORRESPONDANTES

TERMINALES
CORRESPONDIENTES

TAPE OFF (NOT USED)

RUBAN RETIRÉ
(NON UTILISÉ)

DESPRENDIMIENTO
(NO UTILIZADO)

W2

W1

W2

W2

W1

Y1

W2

W2

W2

W

W

W2

Y

Y

Y

Y

W

W2

W1

W

E

W2

W

H2

W2

W

W2

O

O

O

O

O

V

O

O

O

R

R

R

R

O

O

O

Y1

Y1

O

O

O

O

O

RC

R

R

R

R

R

R

R

RED

R

R

R

V/VR

V/VR

V/VR

V/VR

R

R

R

R

R

R

R

R

V/VR

R

R

R

Y

Y

Y1

Y

Y

Y

Y, W1

Y

Y

Y

Y

Y

M

M

M

M

Y

Y

Y

Y

W1

W1

W1

Y

C

Y

Y

Y

G

G

G

G

G

G

G

G

G

G

G

G

F

F

F

F

G

G

G

G

G

G

G

G

F

G

G

G

X2

E

E

E

E

E

to W2

E

X2

E

E

E

E

E

E

X2

E

E

E

E

E

B

B

W1

B

Z

B

C

C

X

X

C

C

C

C

BLACK

B

B

C

X

X

X

X

C

X

C

B

C

C

X

X

X

C/X1

B

C

T

T

L

X

L

L

F

L

L

L

L

L

L

F

L1

L

X

L

TYPICAL 24 VOLT, SINGLE-STAGE HEAT PUMPS AND

2-STAGE HEAT / 1-STAGE COOL HEAT PUMP SYSTEMS

WITH NO EMERGENCY HEAT WIRE

E

G

Y1

R B/O

Y2

W2

C

+

-

REVERSING

VALVE

BLOWER

FAN

HEAT

PUMP

SYSTEM

XFMR

System
Common

AUX.

HEAT

# 1

**Refer To

Wiring Note #1

LES POMPES À CHALEUR À UN ÉTAGE TYPIQUES DE 24 VOLTS

ET LES SYSTÈMES DE POMPE À CHALEUR À 2 ÉTAGES DE CHALEUR /

1 ÉTAGE DE REFROIDISSEMENT SANS FIL DE CHAUFFAGE D'URGENCE

E

G

Y1

R B/O

Y2

W2

C

+

-

ROBINET

INVERSEUR

VENTILATEUR

SOUFFLANT

POMPE À

CHALEUR

SYSTÈME

XFMR

Système
commun

AUX.

CHALEUR

N° 1

** Reportez-vous à la note
de câblage numéro 1

TYPICAL 24 VOLT, 2-STAGE HEAT / 1-STAGE COOL

HEAT PUMP SYSTEMS

WITH EMERGENCY HEAT WIRE PRESENT

# 2

E

G

Y1

R B/O

Y2

W2

C

+

-

EMERGENCY

HEAT

BLOWER

FAN

HEAT

PUMP

SYSTEM

XFMR

REVERSING

VALVE

System
Common

AUX.

HEAT

BOMBAS TÍPICAS DE CALEFACCIÓN DE UNA FASE Y SISTEMAS

TÍPICOS CON BOMBA DE CALEFACCIÓN DE 2 FASES

Y AIRE ACONDICIONADO DE 1 FASE, TODOS DE 24 VOLTIOS

E

G

Y1

R B/O

Y2

W2

C

+

-

VÁLVULA DE

INVERSIÓN

VENTILADOR

BOMBA DE

CALEFACCIÓN

SISTEMA

XFMR

Sistema
Común

CALEFACCIÓN

AUX.

#1

**Consulte la Nota
de cableado #1

LES SYSTÈMES DE POMPES À CHALEUR À

UN ÉTAGE DE REFROIDISSEMENT / 2 ÉTAGES DE CHAUFFAGE

TYPIQUES DE 24 VOLTS AVEC UN FIL DE CHAUFFAGE D'URGENCE

N° 2

E

G

Y1

R B/O

Y2

W2

C

+

-

CHAUFFAGE

D'URGENCE

VENTILATEUR

SOUFFLANT

POMPE À

CHALEUR

SYSTÈME

XFMR

ROBINET

INVERSEUR

Système
commun

AUX.

CHALEUR

SISTEMAS TÍPICOS CON BOMBA DE CALEFACCIÓN DE 2 FASES

Y AIRE ACONDICIONADO DE 1 FASE DE 24 VOLTIOS,

CON CABLE DE CALEFACCIÓN DE EMERGENCIA

#2

E

G

Y1

R B/O

Y2

W2

C

+

-

CALEFACCIÓN DE

EMERGENCIA

VENTILADOR

BOMBA DE

CALEFACCIÓN

SISTEMA

XFMR

VÁLVULA

DE INVERSIÓN

Sistema
Común

CALEFACCIÓN

AUX.

Advertising