Setup – Lexicon Digital Controller MC-12 User Manual

Page 99

Advertising
background image

MC-12

Setup

3-55

INTERNAL NOISE TEST

Opens the INTERNAL NOISE message shown on the previous page,
which indicates that the internal noise test generates loud
calibration noise signals.

When the INTERNAL NOISE message opens:

Press the

arrow button to open the SPEAKER LEVEL ADJUST

menu shown on the previous page. When the SPEAKER LEVEL
ADJUST menu opens, the internal noise test automatically
begins.

Press the

button to skip the internal noise test.

During the internal noise test, the MC-12 sends calibration noise
signals to each speaker in the order shown on the SPEAKER LEVEL
ADJUST menu. The cursor automatically scrolls through output level
parameters, highlighting each parameter as the MC-12 sends the
calibration noise signal to the corresponding speaker. The
calibration noise signal is sent to each speaker for about 4 seconds.

Note:

When the internal noise test begins, the MC-12 automatically sets
volume level to +0dB. Avoid adjusting the master volume level while
the test is in progress to achieve THX reference levels (75dB).

INTERNAL NOISE TEST LEVELS CALIBRATION MANUAL SPEAKERS SETUP

To manually calibrate output levels during the internal noise test:

1. Set the SPL meter to “C” weighting and “SLOW” response.

2. Press the

or

arrow button to highlight the desired

output level parameter. Then, quickly press the

button to

select this output level parameter. The horizontal bar graph
shown on the previous page will open on the on-screen display
and automatic scrolling will stop.

Note:

During the internal noise test, it is possible to select an output level
parameter just as the cursor is about to automatically scroll to the
next parameter, causing the MC-12 to send the calibration noise
signal to both speakers. If this occurs, reselect the desired speaker.

3. When the horizontal bar graph opens, press the

or

button to select the output level that achieves a 75dB SPL
meter reading from the primary listening position.

4. Press

to close the parameter. The internal noise test will

continue and automatic scrolling will resume.

5. Repeat steps 2, 3, and 4 until all desired output levels have

been set.

SPEAKERS

SETUP

MANUAL

LEVELS CALIBRATION

INTERNAL NOISE TEST

Advertising