D. Immediately remove all low powered batteries to avoid leakage and

damage.

E. Opening the casings invalidates the warranty. Do not try to repair the

unit. Contact La Crosse Technology for repairs.


TROUBLESHOOTING

Problem: The LCD is faint.
Solution: 1) Set the LCD contrast to a higher level.

2) Replace batteries.

Problem: No outdoor temperature is displayed.
Solution: 1) Remove all batteries, reinsert into the remote temperature sensor

first, then into the indoor weather station.

2) Place remote temperature sensor closer to the indoor weather station.
3) Be sure all batteries are fresh.
4) No other interfering sources are being used (such as computer

monitors, TV sets, headphones, or speakers) in the vicinity. The
signal travels in a straight line, an electrical source near that “line”
may cause interference.

Problem: Temperature, humidity, or air pressure is incorrect.
Solution: 1) Check/Replace batteries.

2) If multiple remote sensors are in use, check location with

corresponding “boxed numbers.”

3) Move away from sources of heat/cold.
4) Adjust relative air pressure to a value from a reliable source (TV

radio, etc.).

5) The indoor weather station and remote sensors are calibrated at the

factory. If there is a consistent problem, please call La Crosse
Technology.

Problem: “- -” in humidity display.
Solution: 1) Humidity is below 1%.
Problem: WWVB time and date will not set or update
Solution: 1) Wait until overnight for signal to be received

2) Move indoor weather station away from sources of electricity
3) Place indoor weather station in window facing Colorado
4) The first reception is most difficult, as the indoor weather station

needs five continual minutes of clear signal reception. After the
initial time/date set, the indoor weather station only requires one
full minute of clear reception each night.


SPECIFICATIONS

Temperature measuring range

Indoor

14.2

°F to 139.8°F with 0.2°F resolution

(-9.9

°C to +59.9°C with 0.1°C resolution)

(“OFL” displayed if outside this range)