NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Model

F (1)

G

H

J

M

C20

22”

559mm

1”

356mm

22-1/2”

572mm

5-1/”

133mm

50-1/2”

1283mm

E20

22”

559mm

1”

356mm

22-1/2”

572mm

5-/”

133mm

5”

1143mm

C20 with mantel

and/or side

shields

u

22”

559mm

1”

356mm

22-1/2”

572mm

5-1/”

133mm

8”

965mm

* Reduced clearances may be available for A, B, C and D

dimensions per NFPA 211 - latest edition, Standard for

Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli-

ances (in Canada CSA B5 - latest edition). See section on

“Reduction of Appliance Clearance with Specified Forms of

Protection.”

** Side view of optional mantel deflector shown.

u

Elite™ E20 - Not tested for reduction of clearances

(1)Hearth extension reductions: 2” (51mm) reduction for 2”

(51mm) raised hearth. (USA) 1” minimum hearth exten-

sion on all stoves as measured from the door opening of the

unit. (Canada) 18”(50mm) minimum hearth extension on

all stoves as measured from the door opening of the unit.

Minimum distance of floor protection to the side = 8” (200mm).

This is measured from the sides of the door opening in the

USA and from the sides of the insert in Canada.

h

earTh

P

roTecTion

The hearth and/or floor protection must be a thermally rated

non-combustible hearth/floor protector meeting or exceeding

a thermal rating of k=.84 or equivalent with a listed thickness

of listed thickness of 3/4" (19mm) minimum in the USA and

Canada. The covering must extend USA-16”/Canada-18”

(C260) and 22” (E260) in front of the heater and 8” to the

side (measured from door opening in the USA and measured

from the side of the unit in Canada).

Top Facing / Trim

Side Facing Materia

l

SIDE WALL

C

E (USA)

D

B

A

COMBUSTIBLE MANTEL

Insert

Maximum Mantel Depth = 9” (229 mm)

Hearth Protection

E

(Canada)

M

6-1/2”

165mm

F

**

J

G

H

Mantel

Hearth Protection

Trim

Model

*A

*B

*C

*D

E(1)

C20

0”

762mm

20”

508mm

20”

508mm

15”

381mm

8”

200mm

E20

2”

584mm

17”

432mm

20”

508mm

15”

381mm

8”

200mm

C20 with mantel

and/or side

shields

u

17”

432mm

1-1/2”

368mm

20”

508mm

8”

200mm

8”

200mm

Notes

• Facing material that projects more than /” (19mm) from

the wall is considered a mantel or side wall.

• MINIMUM FIREPLACE OPENING 22-1/2” (572mm) High x

28-1/2” (72mm)

r

equireD

c

learances

WARNING: BE ABSOLUTELY SURE THE DISTANCE BE-

TWEEN THE HEATER AND THE SURFACE OF ANY COM-

BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN

ON THIS PAGE.

Figure 4

Figure 5