Check & Adjust

TPS1200

91

Every angle measured in the daily work is corrected automatically if the compensator
and the Hz-corrections are activated in the instrument configuration. Select Main
Menu: Config...\Instrument Settings...\Compensator
to check the settings.

View current
adjustment errors

The currently used adjustment errors can be viewed under Main Menu:
Tools.../Check & Adjust...\Current Values.

Mechanical
adjustment

The following instrument parts can be adjusted mechanically:

Circular level on instrument and tribrach

Visible red laser beam of reflectorless EDM - option

Laser plummet

Optical plummet - option on tribrach

Allen screws on tripod

Precise
measurements

To get precise measurements in the daily work, it is important:

To check and adjust the instrument from time to time.

To take high precision measurements during the check and adjust procedures.

To measure targets in two faces. Some of the instrument errors are eliminated
by averaging the angles from both faces.

Refer to "5.2 Preparation" to find more important points.