Wiring diagram, Continued), Warning – Lochinvar 000 through 2 User Manual

Page 79: Ignition module, Status led

Advertising
background image

79

Wiring Diagram

(continued)

1,500,000 - 1,300,000 - 2,000,000 Btu/hr Models

50 Hz Limit

Resistor

1.2K Ohm

Y

TO VFD
TERMINAL
NUMBER 15

TO VFD

TERMINAL

NUMBER 14

OPTIONAL 50 Hz LIMIT RESISTOR

P

OPTIONAL

WARNING:

To avoid possible

shock hazard, disconnect power
before servicing.

OPTIONAL

BK

BR

J

3

5

1

4

1

3

1

2

1

4

3

2

1

G

ND

O

H

M

O

U

T

O

H

M

O

H

M

O

H

M

V/

m

a

V/

m

a

1

2

3

1

2

1

2

1

2

1

2

3

4

5

BYPASS

SENSOR

OUTLET

SENSOR

INLET

SENSOR

ENABLE

SWITCH

OA

SENSOR

2

1

CHASSIS
GROUND

RUN /STOP SWITCH

2
1

2
1

2
1

2
1

6

5

78

9

1

0

11

OA SENSOR

INLET SENSOR

BYPASS SENSOR

F2

F1

-

+

IGNITION

MODULE

24VAC GAS

VALVE

Louver

Proving Sw

AIR

SWITCH

Low

Gas

High

Gas

FLOW

SWITCH

Blocked

Drain

FC-FC+

S1

L1

L2

S2/FS

L

IN

E

N

E

U

T

R

A

L

11

10

9

6

4

3

2

1

N/A
TH
PI

LV1

PS
FF
M/S
FF

HOT

SURFACE

IGNITER

LBL90002 REV A

GY

BK

W

120VAC GAS

VALVE

Y

R

R

GAS VALVE RELAY

NO

COM

NO

COM

NO

NO

NC

C

NC

NO

C

NO

NC

C

NO

NC

C

NO

NC

C

EXT. GAS VALVE

Y

R

LV2
RESET

8

7

5

MV

5

4

2

1

O

O/

BK

O

O

O

PU

PU

PU

R

R

R

O

BL

GY

M

T

BR

T

W

BK

W

BK

COMMUNICATION

CABLE #1

REAR

COMMUNICATION

CABLE CONNECTION

CONTROL PANEL

COMMUNICATION

CABLE CONNECTION

COMMUNICATION

CABLE #3

BYPASS

VALVE

R

W

BK

GY

GY

GY

GY

NO

COM

LOUVER

RELAY

LOUVER

RELAY

CONTACTS

BLOWER

ASSEMBLY

R

O

T

A

T

IO

N

R

O

T

A

T

IO

N

STATUS

LED

BK

BK

Y

Y

Y

BK

Y

BR

BL

Y

BL/BK

BL

IGNITION

RESET

BL

AT OPEN

BK

BK

R

OPTIONAL

VENT VALVE

OPTIONAL

OPTIONAL

STD.

3

2

1

4

EXT. GAS

VALVE

UVERS

LOUVER

CONTACTS

COMMON

CLOSED INPUT

OPEN INPUT

BK

W

120VAC

OUT

INLET

SENSOR

2

1

1

2

3

1

2

3

(2) Where possible, switches and circuitry are shown in power off state.

NOTES:

(3) When replacing wiring, use wire of equal or higher temperature and gage.
(4) Schematic shows electrical connections only. Please refer to wiring diagram in

owner's manual for routing and pin-outs for all connector blocks.

(1)

WARNING:

To avoid possible shock hazard, disconnect power before servicing.

BR

INPUTS

1

1

1

1

1

BK

W

Y

BR

BL

R

NOTE:

DO NOT DISCONNECT

CABLE FROM BLOWER.

G

OUTLET SENSOR

COMMUNICATION

CABLE #1

1

PU

PU

PU

PU

Y

PU

PU

COMMUNICATION

CABLE #2

PU

W

W/BK

(5) Pump delay is standard on water heaters.

Y

OR

TOGGLE

SWITCH

MANUAL

OVERRIDE

C 1

2

Y

4

3

2

BK

W

R

R

BK

W

BLOCKED

DRAIN

PU

CO

M

MO

N

T

BR

BL

O

C

KE

D

O

PE

N

1

2

3

J3

1

2

3

P
U

24 VAC

O

NC

C

O/BK

PU

BL

Y

Advertising
This manual is related to the following products:

000