Fireplace insert installation, Minimum clearances, Insert placement requirements – Lopi Answer Wood Stove User Manual

Page 19: Hearth requirements, Masonry fireplace requirements

Advertising
background image

Fireplace Insert Installation

(for qualified installers only)

19

© Travis Industries

100-01166

4040907

Insert Placement Requirements

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the insert

Insert and hearth must be installed on a level, secure floor

The minimum clearances, facing, and hearth requirements in Figure 17 must be met (follow the
clearances for the type of fireplace being used - either masonry or zero-clearance).

Side

Wall

Combustible Mantel

Combustible Top Facing

Non-Combustible

Hearth

Facing

Masonry

Fireplace

Minimum Clearances

k

l
m

n

o

p
q

x

Sidewall to Insert

Side Facing
Top Facing

Mantel to Insert

Hearth (Front)*

Hearth (Side)
Front of Insert

Extension onto Hearth

13"

9-1/2"
12"

15-1/2"

16"

8"
36"

3"

* Does not include the distance the insert

extends onto the hearth (dimension "x").

q

l

k

p

x

o

n

m

ZC (Metal)

Fireplace

30"

12"
12"

24"

16"

8"
36"

3"

Figure 17

Hearth Requirements

Must extend 16" in front of the insert and 8" on both sides (min. 19" deep by 39-5/8" wide)

Must be non-combustible and at least .018" thick (26 gauge)

Masonry Fireplace Requirements

Chimney must have a clay tile liner or a stainless steel liner (positive connection)

Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert

Chimney height: 15' minimum; 33' maximum.

Entire fireplace, including chimney, must meet local building requirements

Advertising