GETTING STARTED

Logicube Omniclone Xi ™ User’s Manual

11

If an error occurs during cloning, the Status indicator
lights on the front panel will shut off. If one of the
drives caused the error to occur, the Status LED of
the drive will remain lit.

The AMBER light on the light bar lights up when the
unit prompts the user to enter information during a
cloning or diagnostic operation.

The RED light will come on if a problem is
encountered during cloning or any other operation. If
this occurs, check the screen for an error message
and instructions on what to do next.

Installing and Removing the Light Bar

The light bar is attached to the back of the Omniclone
Xi unit and can be removed if desired. This will not
affect the performance of the unit.

1. To install the light bar on the OCXi or the

OCX5i, it first needs to be attached to the back
of the unit with four supplied thumb-screws.

NOTE: The OCX2i does not come with a light
bar, though one can be purchased separately.

2. Attach the light bar’s power cable to the six-hole

Molex™ connector that is located on the back
of the unit to the right of the Compact Flash
Drive slot.

3. Light bar removal is the opposite of installation.

Figure 2. Buttons and Interface