Lucent Technologies Definity Audix System Release 4.0 User Manual

Page 29

Advertising
background image

DEFINITY AUDIX System Release 4.0
System Description Pocket Reference

585-300-214

Issue 1

May 1999

Design and Operation

2-13

Operating Requirements

Table 2-4

shows the system’s atmospheric requirements.

Table 2-4.

Atmospheric Requirements

Table 2-5

shows the system’s tolerance for airborne contaminants.

Temperature

1

(° F)

1.

For customer sites at altitudes above 5000 feet, subtract 1°F from the
maximum temperature for every 1000 feet over 5000. For example,
the maximum temperature at 6000 feet is 84°F; the maximum
temperature at 7000 feet is 83°F

Relative humidity (%)

Air pressure (psi)

65 to 85

20 to 60

9.4 to 15.2

Table 2-5.

Air Purity Requirements

Contaminant

Average Concentration

Total particulate matter, including the following:

Dust

Lint

Carbon particles

Paper fiber

Metal fragments

185.00 microgram/m

3

Nitrate in particulate matter

12.00 microgram/m

3

Corrosive gases

Total hydrocarbons equivalent to methane

10.00 ppm

Sulphur dioxide

0.20 ppm

Oxides of nitrogen

0.30 ppm

Total oxidants equivalent to ozone

0.05 ppm

Hydrogen sulfide

0.10 ppm

Advertising