Basic Operation

CX Power Amplifiers

2-3

1

2

2. Channel Status LEDs

Provide an at-a-glance view of the status of each channel as
indicated in the table below:

Note:

When the main power transformer temperature
exceeds 100˚C:
• the transformer will deactivate
•the channel status LEDs will no longer be lit
•the red standby LED will flash rapidly

Color Status

Constant Blue

Normal Operation

Constant Bright Blue

Indicates the audio signal is clipping. Reduce volume level to help
eliminate potentially damaging audio signals from reaching the speakers.

Flashing Blue

The temperature of the individual amplifier heatsink is above 95˚C. If this
occurs, the channel will not pass audio. The channel status LED will return
to constant blue when the temperature of the amplifier card returns to
normal. Then the channel will automatically resume passing audio.

All Channels Flashing
Blue

The temperature of the chassis is above 58˚C, and the amplifier will no
longer pass audio. After the chassis temperature returns to normal, all the
channel status LEDs will return to constant blue and the amplifier will
resume normal operation.