MATERIAL SAFETY DATA SHEET


Page

2

of

3

CP-771

Section 6: Accidental Release Measures


Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix
AAA Toner Vacuum or 3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal
injury. Remove residue with soap and cold water.
Miscellaneous: Keep product out of sewers and watercourses.
Personal protection: Avoid inhalation of dust.

Section 7: Handling and Storage


Special Handling:


Cleanse skin after contact before breaks or meals, and end of workday.
Do not handle in areas where the wind blows.
Minimize the breathing of dust.

Special Storage:

Avoid direct sunlight. Keep out of reach of children. Store in a cool, dry place. Below 35C (95F)

Section 8: Exposure Control and Personal Protection Information:


Respiratory Protection: none required under normal use. Hand Protection: none required under normal use.

Eye Protection: none required under normal use. Skin Protection: none required under normal use.

Section 9: Physical and Chemical Properties

CHARACTERISTICS:
Appearance: Cyan

Melting

point:

N/a

Form: Powder

Vapor

pressure:

N/a

Odor: Slight

plastic

odor Vapor

density:

N/a

Solubility in Water:

Insoluble

Evaporation rate:

N/a

Specific gravity:

~ 5 g/cm

3

Boiling point:

N/a

Section 10: Stability and Reactivity


Conditions to avoid: none

Hazardous decomposition products: will not occur

Polymerization: none

Section 11: Toxicological Information:


Ames test:

negative

Acute oral toxicity: > 5000mg/kg
Carcinogenicity: no data is available on this product.
Teratogenicity: not available

Section 12: Environmental / Ecological Information


Bioaccumulation: Not known in bioaccumulation
Environmental degradation: not known

Section 13: Disposal Consideration


Used developer should be disposed of under conditions that meet all federal, state and local environmental regulations. Disposal
regulations vary from locality to locality; therefore consult your local Lanier office or the EPA to determine the proper method for
disposal. Do not incinerate loose or spilled developer.