ROTOR FIELD FEEDBACK AND
AUXILIARY POWER

The AC voltage developed in the field winding is fed to
the full wave bridge. The DC output of the bridge is fil-
tered by the field capacitor and controlled by the out-
put rheostat.

This filtered and controlled feedback voltage is fed to
the rotor winding via the brush and slip ring configura-
tion. As the feedback voltage is increased or de-
creased, the outputs of the weld and auxiliary wind-
ings are likewise increased or decreased.

When full field voltage is applied to the rotor and the
engine is running at high speed (3700 RPM), a 230
VAC voltage is developed in the stator auxiliary wind-
ing. This winding is tapped to provide 115 VAC. The
two voltages (115 VAC and 230 VAC) are connected to
the appropriate receptacles and offer 4000 watts
(total) of AC power.

THEORY OF OPERATION

POWER-ARC 4000

E-2

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

FIGURE E.3 – FIELD EXCITATION AND AUXILIARY POWER

ENGINE

STATOR

STATOR

ROTOR

REACTOR

BRIDGE

CAPACITOR

RHEOSTAT

115 AND 230VAC

RECEPTACLES

OUTPUT

TERMINALS

ROTATION

MECHANICAL

SLIP

RINGS

ROTOR

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.