Lennox Hearth VIS35 User Manual

Page 7

Advertising
background image

7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

14-3/4”

(375mm)

22-1/2”

(572mm)

27-3/8”

(695mm)

d

imensions

The gas line screws into the gas valve at the back of the

stove 5” in from the right side of the stove and 4-3/16” up

from the base of the unit.

p

reparing

y

our

v

intage

™ s

tove

f

or

i

nstallation

Read all instructions before beginning your installation. If

instructions have not been read carefully, your installation

could void your warranty and may create a serious fire,

health, or other safety hazard.

The Lennox Hearth Products warranty will be voided if one

of the following occurs:

• Installation of any damaged stove or vent system

component.

• Unauthorized modification of the direct vent system.

• Installation other than as instructed by Lennox Hearth

Products, Security™ Chimneys, or Simpson Dura-

Vent.

• Installation of any stove or vent system component not

manufactured or approved by Lennox Hearth Products,

Security™ Chimneys, or Simpson Dura-Vent.

When planning the installation for your Vintage, it’s neces-

sary to consider the following:

• Where the unit is to be installed

• The vent system configuration to be used

• Gas supply (NG or LP)

• Electrical wiring

• Optional accessories (blower, wall-mounted or remote

thermostat, cast-iron panels or stove panel inserts)

t

op

v

iew

f

ront

v

iew

Figure 

Figure 

21-3/8”

(543mm)

Rear Vent Dimensions

24-5/8”

(626mm)

s

ide

v

iew

Flue Collar

C/L

Figure 1

p

ipe

C

learanCes

All installations using a vertical termination cap must

maintain one inch clearance between the direct vent pipe

and combustibles. For horizontal runs of pipe, one inch of

clearance to combustibles on the sides and bottom, and two

inches on the top of the pipe is required. See pages 13, 14

and 15 for allowable pipe configurations.

Advertising
This manual is related to the following products: