30

!! CAUTION !!

Please note that a model number change associated with the Baldor Main Fan Motor has been instituted. This
change in motor model number also requires a change in the type of fan belt being used. Therefore, when
replacing a fan belt it is important to note which type of motor is being used.



Use the following fan belt …

when using this main fan motor…

Motor, main fan, 3HP, 1 Phase (60 Hz Model Only) Vendor-35V087T356G1
Motor, main fan, 3HP, 3 Phase (60 Hz Model Only) Vendor-35V426T676G1
Motor, main fan, 3HP, 1 Phase (50 Hz Model Only) Vendor-35V424Q013G1

Gates 6929 (V-Belt, 21/32” x 29”)
Lincoln Part # 390128

Motor, main fan, 3HP, 3 Phase (50 Hz Model Only) Vendor-35V426Y886G1
Baldor Motor P/N

M3161TA

– Lincoln Production #4060274

Gates 6931 (V-Belt, 21/32” x 31”)
Lincoln Part # 508202EP

Baldor Motor P/N 35S270T356 – Lincoln Production #4060276





This motor requires the
following fan belt:

Lincoln Part # 508202EP
Dimensions: 21/32” x 31”

This motor requires the
following fan belt:

Lincoln Part # 390128
Dimensions: 21/32” x 29”

This motor requires the
following fan belt:

Lincoln Part # 390128
Dimensions: 21/32” x 29”

Baldor Motors:

M3161TA

35S270T356

Baldor Motors:

35V424Q013G1

35V087T356G1

Baldor Motors:

35V426T676G1

35V426Y886G1